Radiation Safety
Radiation Protection and Safety for Nuclear Gauge Operators (NDG)
Nuclear density gauge safety training for operators of fixed and portable nuclear gauges in plants, processing facilities and construction sites: level, density, moisture and thickness gauges and belt weighers. It combines theory with hands-on work on the participants' own gauges and covers the training that national regulations require for personnel who work with radioactive sources.
Overview
About the programme
Duration
3 days
Training hours
18 hours
Delivery
At your facility or in a venue arranged by the Center
Language
Arabic or English
Objectives
Training outcomes
- Understand the operating principle of a nuclear gauge and its components: the source, the shielding, the shutter and the detector.
- Estimate doses around gauges during operation and maintenance, and apply the rules of time, distance and shielding.
- Carry out periodic checks: shutter integrity, leak (wipe) testing and reading monitoring instruments.
- Respond correctly to faults and incidents: a stuck shutter, damaged shielding, and a lost or stolen source.
- Comply with the licensing, record-keeping and notification requirements set by the regulatory body.
Content
What the programme covers
Day 1: Foundations
- The nature, sources and types of ionising radiation: gamma, beta and neutrons.
- Dose quantities and units, occupational and public limits, and the ALARA principle (as low as reasonably achievable).
- Biological effects of radiation and the three means of protection: time, distance and shielding.
Day 2: The gauge and working on it
- Construction of a nuclear gauge: the sealed source, the housing and shielding, the shutter mechanism, and the detector and processing unit.
- Source types common in gauges: caesium-137, cobalt-60, americium-241/beryllium and krypton-85.
- Safe work procedures before, during and after maintenance, and applying radiological lockout/tagout (LOTO).
- Practical exercise: measuring the dose rate around an installed gauge in the open and closed positions, and documenting the results.
Day 3: Monitoring, emergencies and compliance
- Monitoring and survey instruments, their calibration and functional checks, and leak (wipe) testing.
- Emergencies: a stuck shutter, fire or collapse near the gauge, loss of the source, and the limits of what the operator does and what is referred to the Radiation Protection Officer.
- Licensing and records: the source register, periodic inspection records, notification of transfer and disposal, and facility responsibilities.
- Final theory and practical evaluation.
Who it is for
Target audience
Nuclear gauge operators, maintenance and instrumentation technicians, and shift supervisors in cement, petrochemical, mining, paper and steel plants and water treatment plants, as well as those using portable moisture-density gauges on road and construction projects.
Method
Delivery method
Focused instruction combined with hands-on work on the facility's gauges and monitoring instruments; a short workshop for unit managers can be added on the final day. Delivered at your facility or in a venue arranged by the Center, in Arabic or English according to the participants.
Questions
FAQ
What is a nuclear gauge, and where is it used?
A nuclear gauge measures density, moisture, level or thickness without contact, using a sealed radioactive source such as caesium-137 or americium-241/beryllium. Fixed gauges sit on silos, pipes and conveyor belts in cement, mining, petrochemical and paper plants; portable nuclear density gauges (moisture-density gauges) test soil and asphalt compaction on road and construction sites.
Do nuclear gauge operators need radiation safety training?
Yes. National regulations require training for personnel who work with radioactive sources, and this programme covers those training requirements for gauge operators, maintenance technicians and shift supervisors.
How much radiation exposure does a nuclear density gauge give?
In normal operation the source is held behind its shield and shutter; exposure rises during maintenance, with a stuck shutter or with damaged shielding. Participants practise measuring dose rates around the gauge with survey meters, shutter open and closed, and applying time, distance and shielding.
Does the programme cover risk assessment and emergencies?
Yes: estimating doses during operation and maintenance, periodic checks such as shutter integrity and leak (wipe) tests, and the response to a stuck shutter, fire, or a lost or stolen source, including the limits of what the operator does and what is referred to the Radiation Protection Officer.
Is there a certificate?
Every participant who attends the programme receives a certificate of completion from Technology Experts Training Center, licensed by the Technical and Vocational Training Corporation (TVTC).
Can it be delivered at our site?
Yes. It is delivered at the facility on the gauges the participants operate, or in a hall arranged by the Center, and the theory can be delivered virtually via live broadcast. Duration and topics are adjusted to the organisation's needs, in Arabic or English.
A programme tailored to your organisation
The duration and topics of the programme are adjusted to the organisation's needs, and it is delivered at its site, in a training hall arranged by the Center, or virtually.